數(shù)據(jù)恢復(fù)進(jìn)度查詢: |
|
ST4000VX005通電終端報LED恢復(fù)成功案例
瀏覽: 發(fā)布時間:2022/2/28 15:24:01ST4000VX005通電終端報LED恢復(fù)成功案例
客戶:外地一數(shù)據(jù)恢復(fù)中心
日期:2022.2.23
硬盤型號:ST4000VX005-2LY104 SN:WFN61SN3 FW:CV11 電路板號:100846468
故障現(xiàn)象:硬盤通電不認(rèn)盤,終端報LED錯誤,這種新盤固件有變化,處理方法不一樣,同行發(fā)過來讓我們幫忙處理。
解決方案:收到硬盤后,接到數(shù)據(jù)恢復(fù)工具PC-3000 UDMA Express上,通電檢測發(fā)現(xiàn),終端信息如下:
Boot 0x0100MVM163ACV11
SpinUp
TCC:001A
Trans
Rst 0x0100MVM163ACV11
SAdd:0x0055C47F
NVCScram Saved HB Size:020A
LD: MD_Alloc:00000078 HB_Alloc:0000 MD_Alloc:80380000 HB_Alloc:8032 FlashRestore MD_Saved:00000078 HB_Saved:00000000 MD_CRC:79FF
PP: MD_Alloc:0000B400 HB_Alloc:0000 FlashRestore
PVTSize: 00002C00 CompSize: 0000024A DeCompSize: 00002C00 MD_Saved:0000024A HB_Saved:00000000 MD_CRC:3707
WCD: MD_Alloc:00012000 HB_Alloc:02E6 FlashRestore...............................................................................................................................................................................................................................................................................................................................................................................................
LED:0x000000BD FAddr:0x0000A78A
原板處理固件后,硬盤正常認(rèn)盤,數(shù)據(jù)區(qū)前后都能正常訪問,DE鏡像,數(shù)據(jù)完美恢復(fù)。
天浩數(shù)據(jù)恢復(fù)中心,16年數(shù)據(jù)恢復(fù)經(jīng)驗,您值得信賴!